Products
Solutions
Resources
|
|
Aerospace
Please click here to redirect to the new 3M™ Novec™ site.
Cleaning is an essential process in aircraft production, maintenance and repair to ensure safe operation. Effective cleaning agents must remove a wide range of contaminants, yet be compatible with a wide range of metals, plastics and elastomers.
3M™ Novec™ Engineered Fluids have proven to be highly-effective and versatile aircraft cleaning solvents:
- Effective on a wide range of soils. Excellent materials compatibility
- Can be successfully and economically used in vapor degreasing, tube flushing, spray cleaning and hand wipe operations
- Excellent for the removal of particulate contamination
- Outstanding penetration of tight clearances in complex parts
- Fast drying
- Not hazardous air pollutants (HAPs), low in acute and chronic toxicity
- Nonflammable throughout the cleaning and drying process
- Non-ozone depleting and low global warming potential
3M™ Novec™ Aerosol Cleaners are designed to meet the need for safe, sustainable and effective solvents in a convenient aerosol form. These fast-drying, non-flammable materials
offer a wide margin of worker safety in their intended applications. And, because they are non ozone-depleting and contain no nPB, HFCs or HAPs, they represent a sustainable technology alternative to ozone
depleting solvent cleaners such as HCFC-141b and HCFC-225.
For full details, please see our brochure Using 3M™ Novec™ Aerosol Cleaners for Hand-Wipe and Flush Cleaning in Compliance with the U.S. EPA's Aerospace NESHAP.
Regulatory Status
3M™ Novec™ Engineered Fluids are included in the Significant New Alternatives Policy (SNAP) of the U.S. Environmental Protection Agency (EPA). SNAP lists 3M™ Novec™ 7100 Engineered Fluid and 3M™ Novec™ 7200 Engineered Fluid and components of their azeotropes as "acceptable without restrictions"
for use in precision cleaning, electronics cleaning, metal cleaning and aerosol solvent applications. In addition, Novec 7100 fluid and Novec 7200 fluid have been excluded by the U.S. EPA from the definition of a VOC because they have negligible contribution to tropospheric ozone formation.
Cleaning
3M™ Novec™ Engineered Fluids have proven to be highly-effective and versatile aircraft cleaning solvents:
- Effective on a wide range of soils. Excellent materials compatibility
- Can be successfully and economically used in vapor degreasing, tube flushing, spray cleaning and hand wipe operations
- Excellent for the removal of particulate contamination
- Outstanding penetration of tight clearances in complex parts
- Fast drying
- Not hazardous air pollutants (HAPs), low in acute and chronic toxicity
- Nonflammable throughout the cleaning and drying process
- Non-ozone depleting and low global warming potential
AMS 1526B |
Aircraft Exterior Surfaces |
Novec 7100,
Novec 7200,
Novec 71DE,
Novec 72DE*,
Novec 72DA*
|
| Boeing, D6 17487 |
Exterior and General Cleaners |
Novec 7100,
Novec 7200,
Novec 71DE,
Novec 72DA*,
Novec 72DE*
|
| BAC 5750 |
Solvent Cleaning |
Novec 71DE,
Novec 7100
|
| BAC 5402 |
Oxygen Tool Cleaning |
Novec 71DE,
Novec 7100
|
| ADS 61 PRS |
AAMCOM |
Novec 7100,
Novec 71DE,
Novec 72DE*
|
| Mil Std. 1330 D |
Oxygen System Gauge Cleaning |
Novec 7100 |
| SE-S-0073 |
NASA Oxygen System Verification and Cleaning, Space Shuttle |
Novec 7100 |
* Stating exception of acrylic stress crazing.
To the top
Aerosol Cleaning
3M™ Novec™ Aerosol Cleaners are designed to meet the need for safe, sustainable and effective solvents in a convenient aerosol form. These fast-drying, non-flammable materials offer a wide margin of worker safety in their intended applications. And, because they are non ozone-depleting and contain no nPB, HFCs or HAPs, they represent a sustainable technology alternative to ozone depleting solvent cleaners such as HCFC-141b and HCFC-225.
For full details, please see our brochure Using 3M™ Novec™ Aerosol Cleaners for Hand-Wipe and Flush Cleaning in Compliance with the U.S. EPA's Aerospace NESHAP****.
To the top
Electronics Heat Transfer
3M™ Novec™ Engineered Fluids are unique dielectric materials used to solve a wide range of thermal management challenges. Novec fluids can help reduce component bulk and weight; simplify design; and ensure system reliability. Whether the application is indirect or direct contact, single phase or evaporative, 3M Novec fluids are ideally suited for use as cooling media in demanding applications. Novec fluids are nonflammable, evaporate cleaning in case of spills and maintain low viscosity and high heat transfer efficiency over a wide operating temperature range.
- Excellent dielectric properties
- Wide range of boiling points
- Good materials compatibility
- Low toxicity, non-irritating
- Nonflammable and non-combustible
- Low Global Warming Potential
- Zero Ozone Depletion Potential
3M™ Thermal Management Fluids Brochure PDF 440k
3M™ Thermal Management Fluids for Military and Aerospace Applications brochure PDF 980k
To the top
|
Materials Compatibility Tests
When selecting a cleaning solvent, materials compatibility is as important as the solvent’s cleaning ability. Novec fluids are compatible with a wide range of substrates used in aerospace materials, medical devices, optical components, electronics and other parts requiring very clean, spot-free finishes.
| Test Description |
ASTM# |
Novec 7100 |
Novec 71DE |
Novec 7200 |
Novec 72DA |
Novec 72DE |
| Sandwich Corrosion Test |
F1110 |
Conforms |
Conforms |
Conforms |
Conforms |
Conforms |
| Acrylic Stress Crazing |
F484 |
Conforms |
Doesn't conform * |
Conforms |
Doesn't conform * |
Doesn't conform * |
| Paint Softening Test |
F502 |
Conforms |
Conforms |
Conforms |
Conforms |
Conforms |
| Hydrogen Embrittlement |
F519-77 |
Conforms |
Conforms |
Conforms |
Conforms |
Conforms |
| Hydrogen Embrittlement |
F519,1C |
Conforms |
Conforms |
Conforms |
Conforms |
Conforms |
| Residue Test |
F485 |
Conforms |
Conforms |
Conforms |
Conforms |
Conforms |
| Immersion Corrosion Test |
F483 |
Conforms |
Conforms |
Conforms |
Conforms |
Conforms |
| Cadmium Removal Test |
F483 |
Conforms |
Conforms |
Conforms |
Conforms |
Conforms |
| Low Embrittling Cadmium Plate |
F111 |
Conforms |
Conforms |
Conforms |
Conforms |
Conforms |
| Flash Point |
D56 |
Conforms |
Conforms |
Conforms |
Conforms |
Conforms |
* Novec fluids 71DE, 72DA, and 72DE caused visible stress crazing of the acrylic plastics. Testing performed by Scientific Materials, Inc.